Njengoba i-Modicon ithuthukisa i-PLC yokuqala kulo mhlaba, i-Fieldbus isebenze isikhathi eside emkhakheni we-automation yezimboni njengoba inganikeza izixazululo ezinzile nezomnotho.
Kodwa manje, ngokuvuswa kwe-Industrial 4.0, imishini yasensimini idinga iphuzu elikhudlwana ledatha, ngakho-ke ukuxhumana okukodwa kwe-Master-Slave kufanele kuvumele ukuxhumana kweKlayenti-Isevisi ngesikhathi sokudluliswa kwedatha yesayithi.
Njengamanje izinhlelo zokusebenza ezisetshenziswa kakhulu ze-Fieldbus zijwayele ukudlulela ezinhlelweni ze-Industrial Ethernet.
Ngakho i-ODOT Automation yahlela uhlelo lwe-R&D lwesikhathi eside ukuze inikeze ezinye izixazululo ezizinzile, ezingabizi kumakhasimende ethu.
Nasi isakhiwo somndeni esilula semikhiqizo ye-ODOT.
Iqembu lomkhiqizo we-Fieldbus
Iqembu lomkhiqizo we-Industrial Ethernet
1. Modbus-RTU→Modbus-TCP
Isixazululo esiyisisekelo esinamasango ochungechunge lwe-ODOT-MG
Izinhlelo zokusebenza ze-Modbus-RTU zasendulo ezisekelwe ku-RS485 sithuthukise izinhlobo ezihlukahlukene zemikhiqizo ukusiza ikhasimende lethu libe nendlela yokufika kuzixazululo ze-Modbus-TCP.
Izixazululo eziyisisekelo zine-S2E2/S4E2 yethu.
Uma udinga noma yisiphi isiguquli sephrothokholi ye-Modbus-RTU/ASCII kuya ku-Modbus-TCP esinemisebenzi ye-serial server, futhi i-ODOTS2E2/S4E2 kuzoba ukukhetha kwakho okuphelele.
Ingaxhuma idivayisi ye-Modbus ku-PLC kanye neklayenti ngesixhumi esibonakalayo sokuxhumana se-Modbus TCP.Isekela ukuxhumana kwamaklayenti angu-5 Modbus TCP ngesikhathi esifanayo.Impahla yezindlu yi-aluminium alloy.Ukwakhiwa kuqinile, kuhlangene futhi kuhle ekuklanyweni.Isekela ukufakwa kwe-DIN-rail.Amasignali e-serial ahlinzeka ngokuhlukaniswa okubonakalayo okwakhelwe ngaphakathi.
I-ODOT S4E2 ingasetshenziswa kanyekanye njenge-Master and Slave uma ixhunywe kokubili ne-PLC ne-HMI.
Isixazululo esengeziwe sine-ODOT-AIOBOX16/32 (Imojula ye-IO ehlanganisiwe)
I-ODOT-AIOBOX16/32 iwumkhiqizo ongabizi kakhulu wamaphrojekthi akho onesidingo samaphoyinti e-I/O anomkhawulo.
Kuyimojuli ehlanganisiwe ye-IO enesakhiwo esiyingqayizivele.
Umkhiqizo ungaqoqa isignali ye-I/O (Idijithali, isignali ye-Analog) yedivayisi yasensimini iye ku-PLC, i-HMI noma ikhompuyutha yokusingatha.
Okwamanje iyakwazi ukuzivumelanisa nezimo ku-0-20/4-20/0-24mA futhi inephromoshini enemojula yephrothokholi ye-Modbus TCP/ Modbus RTU, PROFINET, PROFIBUS-DP ne-EtherCAT.
I-AIOBOX-8031, okuyimojula ye-Modbus Adapter, 2*RJ45, 1*RS485 (Modbus-TCP, Modbus-RTU), njengesixazululo sephrojekthi yakho enephoyinti elincane ledatha.
Futhi singasebenzisa umklamo wethu oyingqayizivele we-chip board ukukusiza emikhiqizweni yakho eyodwa edidiyelwe njengesevisi ejulile eyenziwe ngokwezifiso.
Isixazululo esithuthukisiwe sinemojula yethu yakamuva ye-ODOT Remote I/O, okuyisixazululo esihlukile esingabizi kakhulu sephrojekthi yakho esinephoyinti ledatha eliphakathi nendawo nelilikhulu.
Irimothi ye-I/O iyimojula yephrothokholi eguquguqukayo kanye nenhlanganisela yemojula ye-I/O yepulaki nokudlala, izici ezingezansi:
1. I-ODOT eyirimothi ye-I/O ingalengiswa ngenani lamamojula angu-64, imojuli ye-I/O ngayinye yakhiwe ngamashaneli angu-16 futhi ngalinye linenkomba ye-LED.
Isekela inani eliphelele lamaphoyinti angu-1024 we-I/O nepulaki elishisayo;
2. Ikhebula lepuleti elingemuva lemojuli ye-I/O linganwetshwa libe ngamamitha angu-20 ukuze lisetshenziswe kumaphaneli amaningi;
3. I-WTP isuka -40~85℃ inewaranti yeminyaka emi-3;
4. Ubuciko buhambisana nebanga lezimoto;
5. Ibhasi lepuleti elingemuva lejubane elingu-12M, elinamamojula angama-64 wenani ledijithali lesikhathi sokuvuselela ku-2ms kanye nobuningi be-analog ngu-3.4ms;
6. Isekela amaphrothokholi amaningi kanje:
1. Modbus-RTU
2. I-Profibus - DP (DPV0)
3. I-CC-LINK Yezimo Ezikude
4. CANopen DS401
5. I-DeviceNet
6. I-Modbus-TCP
7. Inzuzo
8. I-EtherCAT
9. I-EtherNet/IP
10. I-PowerLink
11. Inkundla ye-CC-Link IE
12. I-CC-Link IE Field Basic
CN-8031: Modbus-TCP Adapter module, 32 Slots, okokufaka & okukhipha max 8192Byte
I-CN-8011: I-adaptha yenethiwekhi ye-Modbus-RTU protocol, 32 slots, the Max.isamba okokufaka nokuphumayo ngu-8192 Byte.
Uma udinga isixazululo kusuka ku-Modbus-RTU kuya ku-TCP kusilawuli kude se-I/O, siphinde sinikeze imojula ekhethekile CT-5321 yayo.
I-CT-5321: i-serial port communication sub-module (RS232, RS485, RS422, noma ichweba le-serial liyazikhethela, lisekela i-Modbus-RTU / ASCII, imodi eyinhloko noma yesigqila, imodi yokudlulisela esobala).
2. I-Profibus-DP→Inzuzo
Isixazululo esiyisisekelo esinamasango ochungechunge lwe-ODOT-MG
I-DPM01: I-Modbus RTU (Inkosi/Isigqila) kuya ku-Profibus-DP (Isigqila), I-Aluminium Alloy Casing, imbobo engu-1 RS485, imbobo engu-1 Profibus-DP
I-PNM02: I-Modbus RTU kuya ku-ProfiNET, i-Aluminium Alloy Casing, imbobo engu-1 RS485 noma i-RS232 noma i-RS422, imbobo eyi-Profinet
I-AIOBOX16/32 iyisixazululo esengeziwe.
I-AIO-X8032: Imojuli ye-Profinet Adapter, 2*RJ45
I-AIO-X8012: Imojula ye-Profibus-DP Adapter
I-Remote I/O iyisixazululo esithuthukisiwe
I-CN-8032: CN-8032:Imojuli ye-adaptha ye-Profinet, izikhala ezingama-32, okokufaka nokuphumayo okuphezulu okungu-1440Byte
I-CN-8012: CN-8012:I-adaptha yenethiwekhi yephrothokholi ye-Profibus-DP, izikhala ezingama-32, i-Max yokufaka.244 Byte, okukhipha Max.244 Byte, iMax.isamba sokufakwayo nokuphumayo singama-288 Byte
Imojuli ye-I/O yesikhathi esizayo ingase isekele ukuguqulwa phakathi kwe-Profinet ne-Pofibus-DP.
3. I-CC-Link → CC-Link IE
Ukusebenzela izixazululo zombili zomndeni we-CC-LINK.
Okwamanje sesiqedile i-CN-8013, okuyi-adaptha yenethiwekhi ye-CC-Link ye-CC-Link Ver.2 evamile
4. I-DeviceNET → I-Ethernet IP
Sihlele ukuthuthukisa le mojula ye-I/O ekude ngonyaka ozayo.
5. I-CANopen→EtherCAT
Isixazululo esiyisisekelo esinamasango ochungechunge lwe-ODOT-MG
Sine-MG-CANEX, okuyisango le-CANopen ku-Modbus TCP/IP.
Lolu cingo lusebenza njengoMphathi kunethiwekhi ye-CANopen, nomsebenzi wokuphatha inethiwekhi ye-NMT, futhi lungaxhunywa ngezisetshenziswa zesigqila ezijwayelekile ze-CANopen.Njengeseva ye-TCP ku
Inethiwekhi ye-Modbus-TCP/IP, idivayisi ingafinyelelwa amaklayenti e-TCP amaningi ngesikhathi esisodwa, futhi ingafinyelela kusilawuli se-PLC nesofthiwe yokucushwa komsingathi.Lokhu kungaxhuma kutheminali yokubona nezinye izinto zokusebenza ukuze kutholakale ukudluliswa kwedatha ebangeni elide.
I-AIOBOX16/32 iyisixazululo esengeziwe.
Imojuli ye-AIOBOX-8033 EtherCAT Adapter
Imojula ye-AIO-X8033 EtherCAT I / O isekela ukufinyelela kwephrothokholi ye-EtherCAT ejwayelekile, futhi i-adaptha yenethiwekhi isekela amamojula we-IO wokunwebeka angama-4.
Imojuli ye-adaptha ye-AIO-X8021 CANopen
Imojula ye-adaptha yenethiwekhi ye-AIO-X8021 CANopen isekela ukuxhumana okujwayelekile kwe-CANopen futhi isekela ukucaciswa kwedivayisi DS401
I-Remote I/O iyisixazululo esithuthukisiwe
I-CN-8033, okuyimojula ye-EtherCAT I/O, isekela ukufinyelela kwephrothokholi ye-EtherCAT evamile.
I-adaptha isekela i-Max.okokufaka okungu-1024 bytes kanye ne-Max.umphumela wamabhayithi angu-1024.Itisekela ama-32 ama-pcs amamojula e-IO anwetshiwe.
Isikhathi sokuthumela: Oct-26-2020