    I-ODOT-PNM02 V2.1

    I-Modbus (inkosi/isigqila, i-RTU/ASCII) iya ku-ProfiNET, i-port serial port engu-2 (RS485/ RS232 / RS422), isekela izikhala ezingama-50, imiyalo engama-200 ku-TIA

    ingosi (ngesofthiwe emisiwe), isekela izigqila ezingu-MAX 60

    ♦ Isekela ukuguqulwa kwephrothokholi phakathi kwe-Modbus ne-PROFINET

    ♦ Isekela i-2* RS485/RS232 noma i-1*RS422

    ♦ Isekela i-Modbus master noma isigqila, futhi isekela i-RTU noma i-ASCII

    ♦ Isekela izinga lokushisa lokusebenza -40〜85°C

    ♦ Isekela indawo yedatha: 2 i-serial Modbus-RTU/ASCII ukuya ku-PROFIBUS esangweni nge-Max.okokufaka 1440 bytesand Max.umphumela 1440 byte

    ♦ Isekela ukusetha kabusha ukhiye owodwa

    ♦ I-ODOT-PNM02 V2.0 isekela izikhala eziphezulu: 50

    ♦ I-ODOT-PNM02 V2.1 isekela izigqila ezingu-60 (imiyalo engu-200 yokufunda nokubhala)

  • I-ODOT-S4E2: 4 I-serial Modbus RTU/ASCII kuya ku-Modbus TCP converter

    I-ODOT-S4E2: 4 I-serial Modbus RTU/ASCII kuya ku-Modbus TCP converter

    ♦ Isekela ukuguqulwa kwephrothokholi phakathi kwe-Modbus-RTU ne-Modbus-TCP

    ♦ Isekela ukuxhumana kwamaklayenti e-TCP ayi-5 ngesikhathi esisodwa

    ♦ I-ODOT-S2E2 isekela i-2*RS485

    ♦ I-ODOT-S4E2 isekela izintambo ze-RS485/RS232/RS422

    ♦ Imbobo ngayinye ye-serial isekela i-Modbus master nesigqila

    ♦ I-ODOT-S2E2:2 i-serial Modbus-RTU/ASCII kuya kusango leseva ye-Modbus-TCP

    ♦ I-ODOT-S4E2:4 i-serial Modbus-RTU/ASCII kuya kusango leseva ye-Modbus-TCP

    ♦ Isekela ukusetha kabusha ukhiye owodwa

    ♦ Imodi yokusebenza yesango: Ukudluliselwa okusobala, ukuhlelwa kwemephu yekheli

  • I-ODOT-S2E2: 2 I-serial Modbus RTU/ASCII ukuya ku-Modbus TCP Converter

    I-ODOT-S2E2: 2 I-serial Modbus RTU/ASCII ukuya ku-Modbus TCP Converter

    ♦ Isekela ukuguqulwa kwephrothokholi phakathi kwe-Modbus-RTU ne-Modbus-TCP

    ♦ Isekela ukuxhumana kwamaklayenti e-TCP ayi-5 ngesikhathi esisodwa

    ♦ I-ODOT-S2E2 isekela i-2*RS485

    ♦ I-ODOT-S4E2 isekela izintambo ze-RS485/RS232/RS422

    ♦ Imbobo ngayinye ye-serial isekela i-Modbus master nesigqila

    ♦ I-ODOT-S2E2:2 i-serial Modbus-RTU/ASCII kuya kusango leseva ye-Modbus-TCP

    ♦ I-ODOT-S4E2:4 i-serial Modbus-RTU/ASCII kuya kusango leseva ye-Modbus-TCP

    ♦ Isekela ukusetha kabusha ukhiye owodwa

    ♦ Imodi yokusebenza yesango: Ukudluliselwa okusobala, ukuhlelwa kwemephu yekheli

  • I-ODOT-DPM01: I-Modbus-RTU kuya ku-Profibus-DP Converter

    I-ODOT-DPM01: I-Modbus-RTU kuya ku-Profibus-DP Converter

    ♦ Isekela ukuguqulwa kwephrothokholi phakathi kwe-Modbus ne-PROFIBUS

    ♦ Isekela i-RS485, RS422 kanye ne-Rs232

    ♦ Isekela i-Modbus master nesigqila, futhi isekela i-RTU noma i-ASCII

    ♦ Isekela indawo yokusebenza engu -40~85°C

    ♦ PROFIBUS-DP: Max.Faka amabhayithi angu-244, Ubukhulu.Okukhiphayo 244 bytes

    ♦ DPM01:1-way Modbus to PROFIBUS isigqila isango, isamba okokufaka kanye okukhiphayo 288 bytes.

    ♦ DPM02: (ukwenza ngokwezifiso) 1-way Modbus-RTU to PROFIBUS isigqila isango, isamba okokufaka kanye okukhiphayo488 bytes.

  • I-MG-CANEX CANopen to Modbus TCP converter

    I-MG-CANEX CANopen to Modbus TCP converter

    I-MG-CANEX Protocol Converter

    CANopen to Modbus TCP protocol converter

    I-MG-CANEX iyisiguquli sephrothokholi kusuka ku-CANopen kuya ku-Modbus TCP.Idivayisi idlala njengomphathi kunethiwekhi ye-CANopen futhi ingaxhunywa kumishini yesigqila evamile ye-CANopen.Ukudluliswa kwedatha kusekela i-PDO, i-SDO, nokulawula amaphutha kusekela ukushaya kwenhliziyo.Isekela ukuthunyelwa komlayezo ovumelanayo kanye ne-asynchronous.

    Njengeseva ye-TCP kunethiwekhi ye-Modbus TCP, idivayisi ingafinyelelwa amaklayenti e-TCP angu-5 ngesikhathi esifanayo, futhi ingaxhunywa kusilawuli se-PLC nezinhlobo ezihlukahlukene zesofthiwe yokumisa.Ingase futhi ixhume i-optical transceiver futhi ibone ukudluliswa kwedatha ebangeni elide.

  • I-ODOT-S1E1 V2.0: I-Serial Gateway

    I-ODOT-S1E1 V2.0: I-Serial Gateway

    Lesi isiguquli esakhiwe i-Sichuan Odot Automation System Co., LTD phakathi kwe-RS232/485/422 ne-TCP/UDP.Lesi siguquli sephrothokholi singaxhuma kalula amadivaysi e-serial port ku-Ethernet futhi sibone ukuthuthukiswa kwenethiwekhi yamadivayisi e-serial port.

    Isiguquli sephrothokholi sisekela umsebenzi "wokudluliswa kwedatha", okungasethwa njengeklayenti noma iseva.Lo msebenzi ungabona kalula ukuxhumana kwedatha phakathi kwe-PLC, iseva namanye amadivaysi e-Ethernet kanye namadivaysi e-serial port.

    Isekela iseva ye-TCP kanye nokudluliselwa okusobala kweklayenti le-TCP
    Isekela ukudluliswa okusobala kwe-UDP kanye namachweba we-serial abonakalayo
    Isekela ukudluliswa okusobala ngephrothokholi noma ngaphandle kwayo.Ukuhanjiswa okusobala kwephrothokholi kusekela i-MODBUS RTU/ASCII
    Isekela imingcele yokucushwa kwesiphequluli seWEB (Imingcele evamile) Izinga le-serial port baud 1200 kuya ku-115200 bps

  • I-ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Interface ku-EtherNet

    I-ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Interface ku-EtherNet

    ♦ Kufakwe embobeni yokuxhumana ye-PPI/MPI/PROFIBUS ye-PLC, ngokuvamile ngaphandle kokunikezwa amandla kwangaphandle

    ♦ Sekela abashayeli bezokuxhumana be-Siemens S7 Ethernet, okuhlanganisa iMicroWIN, STEP7, TIA Portal, WinCC njll.

    ♦ Ihlanganiswe neseva ye-Modbus-TCP, indawo yedatha ye-Modbus ingazenzekela noma ihlelwe kumephu ukuze ibhalise i-S7-200/300/400

    ♦ Ukuxhumeka kwe-S7TCP kanye nokuxhumana kwe-Modbus-TCP kungenziwa ngesikhathi esisodwa

    ♦ Kufika ku-32 oxhumano lwamakhompiyutha abasingathi luyasekelwa

    ♦ I-MPI ukuya ku-S7 Ethernet/Modbus-TCP converter

    ♦ Isekela ukusetha kabusha Ukhiye Owodwa