I-Protocol Converter
-
I-ODOT-DPM01: I-Modbus-RTU kuya ku-Profibus-DP Converter
♦ Isekela ukuguqulwa kwephrothokholi phakathi kwe-Modbus ne-PROFIBUS
♦ Isekela i-RS485, RS422 kanye ne-Rs232
♦ Isekela i-Modbus master nesigqila, futhi isekela i-RTU noma i-ASCII
♦ Isekela indawo yokusebenza engu -40~85°C
♦ PROFIBUS-DP: Max.Faka amabhayithi angu-244, Ubukhulu.Okukhiphayo 244 bytes
♦ DPM01:1-way Modbus to PROFIBUS isigqila isango, isamba okokufaka kanye okukhiphayo 288 bytes.
-
I-ODOT-PNM02 V2.0 / V2.1: I-Modbus-RTU/ASCll noma iphrothokholi engajwayelekile ku-ProfiNet Converter
I-ODOT-PNM02 V2.1
I-Modbus (inkosi/isigqila, i-RTU/ASCII) iya ku-ProfiNET, i-port serial port engu-2 (RS485/ RS232 / RS422), isekela izikhala ezingama-50, imiyalo engama-200 ku-TIA
ingosi (ngesofthiwe emisiwe), isekela izigqila ezingu-MAX 60
♦ Isekela ukuguqulwa kwephrothokholi phakathi kwe-Modbus ne-PROFINET
♦ Isekela i-2* RS485/RS232 noma i-1*RS422
♦ Isekela i-Modbus master noma isigqila, futhi isekela i-RTU noma i-ASCII
♦ Isekela izinga lokushisa lokusebenza -40〜85°C
♦ Isekela indawo yedatha: 2 i-serial Modbus-RTU/ASCII ukuya ku-PROFIBUS esangweni nge-Max.okokufaka 1440 bytesand Max.umphumela 1440 byte
♦ Isekela ukusetha kabusha ukhiye owodwa
♦ I-ODOT-PNM02 V2.0 isekela izikhala eziphezulu: 50
♦ I-ODOT-PNM02 V2.1 isekela izigqila ezingu-60 (imiyalo engu-200 yokufunda nokubhala)
-
I-ODOT-S4E2: 4 I-serial Modbus RTU/ASCII kuya ku-Modbus TCP converter
♦ Isekela ukuguqulwa kwephrothokholi phakathi kwe-Modbus-RTU ne-Modbus-TCP
♦ Isekela ukuxhumana kwamaklayenti e-TCP ayi-5 ngesikhathi esisodwa
♦ I-ODOT-S2E2 isekela i-2*RS485
♦ I-ODOT-S4E2 isekela izintambo ze-RS485/RS232/RS422
♦ Imbobo ngayinye ye-serial isekela i-Modbus master nesigqila
♦ I-ODOT-S2E2:2 i-serial Modbus-RTU/ASCII kuya kusango leseva ye-Modbus-TCP
♦ I-ODOT-S4E2:4 i-serial Modbus-RTU/ASCII kuya kusango leseva ye-Modbus-TCP
♦ Isekela ukusetha kabusha ukhiye owodwa
♦ Imodi yokusebenza yesango: Ukudluliselwa okusobala, ukuhlelwa kwemephu yekheli
-
I-ODOT-S2E2: 2 I-serial Modbus RTU/ASCII ukuya ku-Modbus TCP Converter
♦ Isekela ukuguqulwa kwephrothokholi phakathi kwe-Modbus-RTU ne-Modbus-TCP
♦ Isekela ukuxhumana kwamaklayenti e-TCP ayi-5 ngesikhathi esisodwa
♦ I-ODOT-S2E2 isekela i-2*RS485
♦ I-ODOT-S4E2 isekela izintambo ze-RS485/RS232/RS422
♦ Imbobo ngayinye ye-serial isekela i-Modbus master nesigqila
♦ I-ODOT-S2E2:2 i-serial Modbus-RTU/ASCII kuya kusango leseva ye-Modbus-TCP
♦ I-ODOT-S4E2:4 i-serial Modbus-RTU/ASCII kuya kusango leseva ye-Modbus-TCP
♦ Isekela ukusetha kabusha ukhiye owodwa
♦ Imodi yokusebenza yesango: Ukudluliselwa okusobala, ukuhlelwa kwemephu yekheli
-
I-MG-CANEX CANopen to Modbus TCP converter
I-MG-CANEX Protocol Converter
CANopen to Modbus TCP protocol converter
I-MG-CANEX iyisiguquli sephrothokholi kusuka ku-CANopen kuya ku-Modbus TCP.Idivayisi idlala njengomphathi kunethiwekhi ye-CANopen futhi ingaxhunywa kumishini yesigqila evamile ye-CANopen.Ukudluliswa kwedatha kusekela i-PDO, i-SDO, nokulawula amaphutha kusekela ukushaya kwenhliziyo.Isekela ukuthunyelwa komlayezo ovumelanayo kanye ne-asynchronous.
Njengeseva ye-TCP kunethiwekhi ye-Modbus TCP, idivayisi ingafinyelelwa amaklayenti e-TCP angu-5 ngesikhathi esifanayo, futhi ingaxhunywa kusilawuli se-PLC nezinhlobo ezihlukahlukene zesofthiwe yokumisa.Ingase futhi ixhume i-optical transceiver futhi ibone ukudluliswa kwedatha ebangeni elide.
-
I-ODOT-S1E1 V2.0: I-Serial Gateway
Lesi isiguquli esakhiwe i-Sichuan Odot Automation System Co., LTD phakathi kwe-RS232/485/422 ne-TCP/UDP.Lesi siguquli sephrothokholi singaxhuma kalula amadivaysi e-serial port ku-Ethernet futhi sibone ukuthuthukiswa kwenethiwekhi yamadivayisi e-serial port.
Isiguquli sephrothokholi sisekela umsebenzi "wokudluliswa kwedatha", okungasethwa njengeklayenti noma iseva.Lo msebenzi ungabona kalula ukuxhumana kwedatha phakathi kwe-PLC, iseva namanye amadivaysi e-Ethernet kanye namadivaysi e-serial port.
Isekela iseva ye-TCP kanye nokudluliselwa okusobala kweklayenti le-TCP
Isekela ukudluliswa okusobala kwe-UDP kanye namachweba we-serial abonakalayo
Isekela ukudluliswa okusobala ngephrothokholi noma ngaphandle kwayo.Ukuhanjiswa okusobala kwephrothokholi kusekela i-MODBUS RTU/ASCII
Isekela imingcele yokucushwa kwesiphequluli seWEB (Imingcele evamile) Izinga le-serial port baud 1200 kuya ku-115200 bps -
I-ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Interface ku-EtherNet
♦ Kufakwe embobeni yokuxhumana ye-PPI/MPI/PROFIBUS ye-PLC, ngokuvamile ngaphandle kokunikezwa amandla kwangaphandle
♦ Sekela abashayeli bezokuxhumana be-Siemens S7 Ethernet, okuhlanganisa iMicroWIN, STEP7, TIA Portal, WinCC njll.
♦ Ihlanganiswe neseva ye-Modbus-TCP, indawo yedatha ye-Modbus ingazenzekela noma ihlelwe kumephu ukuze ibhalise i-S7-200/300/400
♦ Ukuxhumeka kwe-S7TCP kanye nokuxhumana kwe-Modbus-TCP kungenziwa ngesikhathi esisodwa
♦ Kufika ku-32 oxhumano lwamakhompiyutha abasingathi luyasekelwa
♦ I-MPI ukuya ku-S7 Ethernet/Modbus-TCP converter
♦ Isekela ukusetha kabusha Ukhiye Owodwa